Free delivery Australia-wide|30-day returns|Track order|My account
07 3485 0008Call Chlorinator Cells
Viron eQuilibrium chlorinator manual guide, with three replacement chlorinator cells from our shop Sources checked 28 Nov 2026
Home/Guides/Viron eQuilibrium chlorinator manual

Viron Equilibrium Chlorinator Manual: Both PDFs, pH, ORP and Fault Codes

Chlorinator Cells
Written by Chlorinator Cells An independent Australian online store for replacement chlorinator cells. We are not AstralPool. Both Viron eQuilibrium chlorinator manual links go to AstralPool's own files, and every figure here comes from them or from AstralPool's pages.
  • Both versions of the Viron eQuilibrium chlorinator manual, free from AstralPool
  • How a Viron eQ chlorinator doses acid and chlorine: eQ2, eQ3 and Ai mode
  • Error codes, pH fault codes and the stabiliser warning
From AstralPool's own manuals Free delivery Australia-wide 30-day returns
  • 2 versions of the manual
  • 18-45 g/h across the EQ range
  • 2:1 water to acid in the dosing tank
  • 400 mL/h maximum acid in auto mode
  • 7.6 factory pH set point
  • 10-20 ppm stabiliser at most with a chlorine probe

Viron eQuilibrium Chlorinator Manual: The Short Answer

There are two. The current Viron eQuilibrium chlorinator manual is H0717000 Rev C, dated 2024, linked from AstralPool's Viron eQuilibrium page. An earlier one, Inst.464 revision 1.9.20, is on AstralPool's eQuilibrium support page. Both are free PDFs. Match the code on your paper copy if you have it.

A Viron eQ chlorinator is a Viron salt chlorinator that also doses acid for pH (eQ2), adds chlorine control by ORP (eQ3), and can run the whole pool in Ai mode. Below are the figures, the acid and stabiliser rules, and the fault codes from the manuals.

Generic Hurlcon and Astral VX replacement cell, another AstralPool type we list
01

Where to Download the Viron eQuilibrium Chlorinator Manual

AstralPool links two versions of the Viron eQuilibrium chlorinator manual. Both are free.

The two Viron eQuilibrium chlorinator manual files, checked 28 November 2026
Current Earlier
Code H0717000 Rev C, dated 2024 Inst.464, revision 1.9.20
Title Viron eQ Salt Chlorinator With Bluetooth, Installation and Operation Manual Viron EQ Salt Chlorinator with Bluetooth, Installation Manual
AstralPool page Viron eQuilibrium product page and eQ support page eQuilibrium support page
PDF Current Viron eQuilibrium chlorinator manual Earlier Viron eQuilibrium chlorinator manual

AstralPool can move files. If a direct link fails, use the Manuals list on the page beside it.

Not the plain Viron, and not every Viron eQ chlorinator is the same

The plain Viron, without pH or chlorine control, has its own manual, Inst463. Our Viron V25 manual guide covers it, and our Astral pool chlorinator manual guide links all seven AstralPool files.

02

Viron eQ Chlorinator Figures and Versions

AstralPool sells the Viron eQ chlorinator in four sizes and three levels of control.

Viron eQ chlorinator sizes, from AstralPool's product page
Model Output Temperate Tropical
EQ18 18 g/h 50,000 L 40,000 L
EQ25 25 g/h 96,000 L 60,000 L
EQ35 35 g/h 130,000 L 80,000 L
EQ45 45 g/h 170,000 L 105,000 L

Every size: 4,000 ppm salt recommended, range 3,000 to 8,000 ppm, pump up to 8.5 A, acid dosing up to 400 mL/h in auto mode and 900 mL/h in manual mode, 4 timers plus 2 light timers.

The three versions of the Viron eQ chlorinator

  • eQuilibrium 2: pH balance.
  • eQuilibrium 3: pH balance and chlorine management.
  • Ai mode: control of pH, chlorine and water flow together.

The Viron eQuilibrium chlorinator manual says Ai mode needs an eQ chlorinator, a pH sensor, a chlorine sensor and an RJ12 communications cable. It aims to turn the pool water over every day, keep enough sanitiser in the water and keep running costs down, adjusting run times, pump speed with a Viron variable speed pump, and chlorine output.

03

Acid, Probes and Start-Up in the Viron eQuilibrium Chlorinator Manual

The Viron eQuilibrium chlorinator manual opens with cautions that matter before the first run.

  1. Dilute the acid 2 to 1

    "A ratio of 2 parts water to 1 part acid (2:1) should always be followed", because the dosing rate is set around the diluted solution.

    Viron eQuilibrium chlorinator manual, H0717000
  2. Balance the water before the probes go in

    The opening caution gives total alkalinity 80 to 140 ppm, calcium hardness 180 to 250 ppm and pH 7.2 to 7.8. A later section of the same manual gives 80 to 120 ppm and pH 7.2 to 7.6, so the narrower figures meet both.

    Viron eQuilibrium chlorinator manual, H0717000
  3. Add a little chlorine first

    Dose the pool with a small amount of chlorine before starting. If no chlorine is sensed, the Viron eQ chlorinator may go into fail safe mode and not start.

    Viron eQuilibrium chlorinator manual, H0717000
  4. Mount the power supply the right way up

    The power supply is rated IP43 for outdoor use and must be installed with the cables leaving from the bottom. Near the pool, follow AS/NZS 3000. AstralPool strongly recommends a registered pool builder, electrician or other qualified person.

    Viron eQuilibrium chlorinator manual, H0717000
04

Running and Dosing a Viron eQ Chlorinator

Day-to-day running from the Viron eQuilibrium chlorinator manual: hours, backwash, and acid with or without sensors.

  1. Start at full output

    AstralPool recommends running a new Viron eQ chlorinator at maximum output, level 8, at first. The manual adds that the chlorine needed rises as the pH rises.

    Viron eQuilibrium chlorinator manual, 6.2 and 6.3
  2. Run it long enough

    Summer: 8 to 10 hours a day, ideally 4 to 5 in the morning and 4 to 5 in the evening, longer in very hot weather if free chlorine is low. The Viron eQ chlorinator must run every day.

    Viron eQuilibrium chlorinator manual, 6.3
  3. Backwash before the first run

    MAINT, BACKWASH, set the time, ACCEPT. Backwash a sand filter for 2 to 3 minutes, then rinse for 1 minute, turning the pump off to move the valve. ABORT stops the cycle at any time.

    Viron eQuilibrium chlorinator manual, 7.3
  4. Dose acid by hand when advised

    MAINT, NEXT, DOSE, then NO, NO, YES, set the litres with Up or Down and ACCEPT. Press POOL MODE once for AUTO.

    Viron eQuilibrium chlorinator manual, 7.5
  5. Without sensors, set a dosing rate

    The base Viron eQ chlorinator comes without pH or chlorine sensors, which are ordered separately. Without them you choose an acid dosing rate from 1 to 10 on the pH set screen, and the unit doses more as chlorine production rises.

    Viron eQuilibrium chlorinator manual, 7.5.1

Where the acid drum goes

To avoid corrosion, the manual says the liquid acid drum should not sit underneath any equipment. Handle hydrochloric acid with extreme care, read its safety data sheet, and do not breathe the fumes.

Winter and chlorine checks in the Viron eQuilibrium chlorinator manual

In winter, run the unit 6 to 8 hours a day, morning and evening, and a lower output may be chosen. Check chlorine after the morning run and aim for 1 to 3 ppm of free chlorine, adjusting the output or the running time.

A low salt warning

Check again in 24 hours. If it is still on, the current manual says to add two 20 kg bags of salt to the shallow end and run the filter for about 6 hours. Salt can take up to a day to dissolve. If the light stays on, have the water tested, and if the salinity is above 4,000 ppm the chlorinator may need checking. The manual notes the Low Salt light may appear as the water gets colder.

Water figures in the Viron eQuilibrium chlorinator manual

pH 7.0 to 7.4 for fibreglass pools and 7.2 to 7.8 for others. Total alkalinity 80 to 120 ppm. Salt around 4,000 ppm and never below 3,000. A 50,000 litre pool needs 200 kg of salt to reach 4,000 ppm.

05

Stabiliser and ORP: The Viron eQ Chlorinator Exception

This is where the eQ differs most from a plain salt chlorinator.

AstralPool does not recommend stabiliser with a chlorine probe

The Viron eQuilibrium chlorinator manual says stabiliser, cyanuric acid, "is not recommended to be used by Astralpool with an eQ chlorinator and Chlorine probe fitted". It explains that stabiliser bonds with chlorine and lowers the ORP reading, so the unit may keep raising chlorine to reach its set point.

If stabiliser is in the water

The manual says to keep it at most 10 to 20 ppm with a chlorine sensor fitted, and to turn the chlorine (ORP) set point down. Ongoing use of trichlor or dichlor keeps raising stabiliser. If extra chlorine is needed, it suggests small amounts of calcium hypochlorite or liquid chlorine, which add none.

Why total alkalinity matters to a Viron eQ chlorinator

Variable pH gives variable ORP readings, and high pH means the unit makes more chlorine than it needs to reach the set point, the manual says. Measuring and adjusting total alkalinity regularly helps hold the pH.

The factory pH set point

Both versions of the Viron eQuilibrium chlorinator manual give a factory pH set point of 7.6.

06

Timers and Reset in the Viron eQuilibrium Chlorinator Manual

Four timers a day for the pump, chlorine and pH, plus two for lights.

Viron eQ chlorinator timers

The current Viron eQuilibrium chlorinator manual says the Viron eQ chlorinator has four timers a day for the filtration pump, chlorine production and pH. From the factory it runs at 08:00 and 16:00 for 4 hours each, and AstralPool says it is most effective in the cooler early morning or evening. The earlier manual adds that light timers only work with the chlorinator and the lights both in Auto.

RESET SYSTEM on a Viron eQ chlorinator

The install menu includes RESET SYSTEM, which returns the unit to factory settings. The manual says to select NO, and use it only "in the case of a system error that can't be cleared".

Bluetooth on a Viron eQ chlorinator

The current manual has a section on the ChlorinatorGo app for Bluetooth control of the Viron eQ chlorinator.

07

Error Codes in the Viron eQuilibrium Chlorinator Manual

When a Viron eQ chlorinator has an error, a message shows on screen and the INFO light flashes.

Faults in the current Viron eQuilibrium chlorinator manual
Fault Possible cause Solution
NO FLOW (NO F) Pump off or valves closed, blue wire off the cell Turn the valves and pump on. Connect the blue sense wire.
LOW SALT (LO S) Salt too low, water cold, cell failed Add salt, turn output down until the water warms, call for service if the cell has failed.
Sense wire disconnected Low conductivity, salt under 4,000 ppm, a calcified or worn cell Check the water temperature and the plates. Test the salt and keep it at 4,000 ppm.
Display blank No power, or a blown fuse Check the power. A service technician replaces the 2A slow blow fuse.
Low or no chlorine Cables, short timer, low output, filter, low stabiliser, low salt, water under 15 degrees, salt over 10,000 ppm Fix each in turn. Over 10,000 ppm the unit cuts out on overload: reduce salt to 4,000 ppm.
Pool water cloudy Chemistry out, acid empty, ORP too low, pool volume set too low, poor flow, too few turnovers pH 7.2 to 7.6, TA 120 ppm, CH 180 ppm, refill acid, ORP 700 mV, raise the volume or turnovers.
PH FAULT X codes in the current Viron eQuilibrium chlorinator manual
Code Meaning
1 No comms, not connected
3 Can't read comms
17 Too much variation in the pH or ORP measurements
18 pH or ORP measurement too high
19 pH or ORP measurement too low

Our pool chlorinator repair guide sets the salt-side faults beside other makers' tables.

08

Replacement Cells for the Viron eQ Chlorinator

When the cell in a Viron eQ chlorinator has failed, these are the generic Viron and Equilibrium cells we list, made by Kawana in Queensland.

Generic Viron and Equilibrium cells in our shop
Cell, as listed Price, delivered
Viron/Equilibrium V18 $621.30
Viron/Equilibrium V25 $889.94
Viron/Equilibrium V35 $1,052.43
Viron/Equilibrium V45 $1,265.34

Generic cells made by Kawana Chlorinator Spares, not by AstralPool. Prices include GST and delivery. We sell cells only, not the pH or chlorine probes. Email us a photo of your cell label before ordering.

09

Viron eQuilibrium Chlorinator Manual FAQs

Short answers from both versions of the Viron eQuilibrium chlorinator manual.

Where can I download the Viron eQuilibrium chlorinator manual?

From AstralPool. The current H0717000 Rev C is on the Viron eQuilibrium product page and eQ support page. The earlier Inst.464 is on the eQuilibrium support page.

What is the difference between eQ2 and eQ3?

AstralPool lists the eQuilibrium 2 with pH balance and the eQuilibrium 3 with pH balance and chlorine management.

What acid mix does a Viron eQ chlorinator use?

2 parts water to 1 part acid. The manual says the dosing rate is set around that dilution.

Can I use stabiliser with a Viron eQ chlorinator?

AstralPool does not recommend it with a chlorine probe fitted. If it is present, keep it at most 10 to 20 ppm and turn the ORP set point down.

Why will my Viron eQ chlorinator not start?

The manual says to dose a little chlorine first: if no chlorine is sensed, the unit may go into fail safe mode and not start.

What does PH FAULT 18 mean?

The pH or ORP measurement is too high, according to the current manual.

What does Ai mode need?

An eQ chlorinator, a pH sensor, a chlorine sensor and an RJ12 communications cable.

How long should a Viron eQ chlorinator run in summer?

8 to 10 hours a day, ideally split between morning and evening, the manual says, and longer in very hot weather if free chlorine is low.

Does a Viron eQ chlorinator come with sensors?

The base model comes without pH or chlorine sensors, which are ordered separately. Without them you set an acid dosing rate from 1 to 10.

How do I backwash with a Viron eQ chlorinator?

MAINT, BACKWASH, set the time, ACCEPT. Before the first run, backwash a sand filter 2 to 3 minutes and rinse 1 minute.

How do I reset a Viron eQ chlorinator?

The install menu has RESET SYSTEM, which returns factory settings. The manual says to use it only for a system error that cannot be cleared.

Sources We Checked

Both versions of the Viron eQuilibrium chlorinator manual and AstralPool's pages were read on 28 November 2026, Brisbane time.

  1. AstralPool, Viron eQ Salt Chlorinator With Bluetooth manual, H0717000 Rev C
  2. AstralPool, Viron EQ Salt Chlorinator with Bluetooth, Inst.464, revision 1.9.20
  3. AstralPool, Viron eQuilibrium Chlorinator with Bluetooth Control: sizes, versions and acid dosing
  4. AstralPool, eQ support page and eQuilibrium support page

Read the Viron eQuilibrium chlorinator manual and think the cell in your Viron eQ chlorinator is the problem? Email the model and a photo of the cell label to info@chlorinatorcells.au, or call 07 3485 0008.